| 1 | Moisture and rainfall exposure Frequent rain, splash zones, coastal humidity, or poor drainage | Water absorption, thickness swelling, dimensional change, and retention of flexural properties after moisture conditioning | ASTM D7031; water absorption is commonly evaluated with ASTM D570; dimensional change may be reported after conditioning | Request conditioned and unconditioned results. Prefer panels with documented drainage details, sealed cut edges where required, and low moisture-related movement. ASTM D7031 is a guide and does not establish one universal pass/fail value. |
| 2 | Solar radiation and UV exposure High-altitude, tropical, desert, or unobstructed south-facing elevations | Color change, surface chalking, cracking, loss of gloss, and change in flexural performance after accelerated weathering | ASTM D7031; accelerated exposure is commonly performed using ASTM G154 fluorescent UV lamps or ASTM G155 xenon-arc equipment | Compare the exposure cycle, irradiance, condensation or water-spray conditions, and evaluation period. Do not compare weathering results unless the test cycle and rating method are equivalent. |
| 3 | Temperature range and thermal movement Freeze-thaw climates, strong daily temperature swings, or dark-colored cladding | Coefficient of thermal expansion, dimensional stability, heat-deflection behavior, and performance after hot/cold conditioning | ASTM D7031; heat-deflection temperature may be measured with ASTM D648; thermal expansion may be measured with ASTM E831 or an equivalent documented method | Use the reported movement to size expansion gaps and attachment slots. Follow the panel manufacturer’s installation temperature limits; do not substitute heat-deflection temperature for a safe service temperature. |
| 4 | Wind pressure and suction Open terrain, high-rise locations, hurricane regions, or exposed corners | Flexural strength, flexural modulus, panel span capacity, fastener resistance, and connection performance | ASTM D7031; flexural properties may be determined using ASTM D6109 or ASTM D790; project wind loads are calculated under the applicable building code, such as ASCE/SEI 7 | Convert the project wind pressure into panel and fastener reactions. Check both positive pressure and suction, especially at corners, edges, parapets, and around openings. |
| 5 | Service and maintenance loads Walkable ledges, exterior screens, guards, soffits, or panels exposed to impact | Bending strength, stiffness, deflection, impact resistance, creep, and fastener pull-out or pull-through resistance | ASTM D7031; applicable structural design loads should be taken from the governing building code. For many U.S. residential deck applications, a 40 psf live-load value is commonly specified by the IRC, subject to jurisdiction and application. | Do not use a decking load value automatically for a façade panel. Define the actual load case, support spacing, span direction, allowable deflection, and safety factors for the specific installation. |
| 6 | Freeze-thaw and cyclic conditioning Regions with repeated freezing, thawing, and wetting cycles | Cracking, delamination, edge damage, dimensional change, and retained strength after conditioning cycles | ASTM D7031 can be used to organize conditioning and performance evaluation; the exact freeze-thaw procedure must be stated in the test report or project specification | Ask for the number of cycles, temperature limits, moisture condition, specimen orientation, and post-test inspection criteria. A generic “freeze-thaw tested” statement is not sufficient for comparison. |
| 7 | Panel layout and attachment system Long runs, tight joints, concealed clips, or mixed substrates | Panel thickness, support spacing, joint width, edge distance, screw or clip capacity, creep under sustained load, and installation tolerances | ASTM D7031 for performance evaluation; fastener and connection design must follow the applicable structural standard, product evaluation report, and local building code | Evaluate the complete assembly rather than the panel alone. Confirm substrate compatibility, corrosion resistance of fasteners, ventilation, drainage, movement joints, and maintenance access. |