| 1 | Shell pressure test | Pressure-containing parts for leakage or structural defects under test pressure. | Check the test medium, pressure, hold time, temperature, and whether the valve is tested in the required position. Confirm that the procedure identifies the applicable product specification. | Pressure and duration should come from the applicable product standard or approved test specification, not an assumed universal value. Request the test procedure and a traceable report. |
| 2 | Seat or closure leakage test | Leakage past the closed sealing surfaces at the specified test differential pressure. | Compare the direction of pressure application, test medium, differential pressure, test duration, and whether the valve is tested as supplied or after cycling. | Acceptance should state the permitted leakage rate or the specified no-leakage criterion. Request the measured result, test conditions, and the acceptance criterion used. |
| 3 | ISO 5208 leakage-rate classification | A standardized way to specify and assess leakage during applicable valve pressure tests. | Ask whether ISO 5208 is explicitly specified, which edition and leakage rate are used, and whether the selected rate is suitable for the valve’s intended service. | ISO 5208 defines leakage-rate classifications; Rate A means no visually detectable leakage during the specified test. Other rates permit defined leakage limits. The selected rate and test conditions should appear in the report. |
| 4 | Pressure-relief set pressure | The pressure at which the relief valve begins to open in accordance with its design and specification. | Compare the stated set pressure with the required water-heater system specification. Check the test medium, pressure ramp, instrument range, and measurement uncertainty. | Request the specified set pressure, measured opening pressure, tolerance, calibration status of the gauge or transducer, and results from the required sample or production test. |
| 5 | Reseating and blowdown behavior | Whether the valve closes again after pressure falls, and how its closing behavior compares with the specified operating limits. | Check that opening and closing pressures are recorded during the same controlled test cycle and that the procedure defines how leakage after reseating is assessed. | Compare measured opening and reseating values with the product specification. Request the recorded pressure cycle and stated allowable limits; these values are not set by ISO 5208 alone. |
| 6 | Discharge capacity or flow test | The valve’s ability to discharge fluid at the capacity required by its intended application. | Compare the flow medium, inlet pressure, outlet arrangement, measurement method, and whether backpressure is controlled or recorded. | Capacity requirements must come from the applicable product standard, system design, or local code. Request the measured flow data and the stated rating basis. |
| 7 | Test medium and cleanliness | Whether the chosen medium and valve condition provide a valid test without introducing avoidable contamination or damage. | Confirm whether water, air, or another medium is used for each test, and whether the procedure specifies filling, venting, drying, or cleaning steps where relevant. | The medium must be suitable for the test and permitted by the governing specification. Request the procedure and any notes on post-test cleaning or preservation. |
| 8 | Temperature and service-condition checks | Whether the valve’s materials and operation are appropriate for the specified water and ambient temperature range. | Check whether tests are conducted at a defined temperature and whether temperature limits, materials, and seals are documented for the intended service. | Compare declared operating limits with the heater-system requirements and applicable product specification. Request material and temperature-condition documentation where required. |
| 9 | Test equipment and measurement traceability | Whether pressure, time, temperature, and flow measurements are reliable and traceable. | Review instrument identification, measurement range, calibration status, calibration interval, and uncertainty where relevant to the acceptance limit. | Request calibration records or instrument references linked to the test report. Measurement capability should be adequate for the specified tolerance. |
| 10 | Sampling, production testing, and report completeness | Whether results can be linked to the tested valve, production lot, and defined inspection plan. | Compare the sampling frequency, serial or lot identification, test date, inspector, procedure revision, and treatment of failed samples. | A useful report records the valve identification, test conditions, measured results, acceptance criteria, equipment references, and pass/fail decision. Verify that the sampling plan meets the applicable specification. |