| Measurement range and accuracy | Confirm the relative-humidity range, stated accuracy, measurement temperature range, and conditions under which accuracy is specified. | Datasheet with accuracy-versus-temperature details, test conditions, and measurement uncertainty information. | Compare specifications at the temperatures and humidity levels expected at the installation site. Treat an accuracy figure without stated conditions as incomplete. |
| Calibration and traceability | Check whether calibration is available for the supplied sensor and whether calibration results are traceable to recognized national or international measurement standards. | Sample calibration certificate showing the measured points, results, uncertainty, date, and calibration laboratory details. | For applications requiring formal traceability, verify the calibration laboratory’s relevant accreditation scope, not only the presence of an accreditation logo. |
| Temperature compensation | Determine whether the sensor includes temperature measurement or compensation and how humidity performance changes across its operating temperature range. | Technical documentation describing compensation method, temperature limits, and any combined temperature-and-humidity performance data. | Check performance across the full expected outdoor temperature range rather than relying only on a room-temperature specification. |
| Response time and recovery | Review response-time conditions, airflow assumptions, and recovery behavior after exposure to high humidity or condensation. | Test data identifying the test method, airflow, temperature, and humidity transition used to determine response time. | Compare response performance under conditions similar to the weather station’s radiation shield and ventilation arrangement. |
| Outdoor environmental protection | Assess resistance to rain, dust, UV exposure, temperature cycling, and condensation. Check whether the sensor needs a separate radiation shield or weather enclosure. | Enclosure protection rating and test documentation where applicable, plus installation and maintenance instructions. | Use an ingress-protection rating, such as one assessed under IEC 60529, only as one part of the assessment; it does not by itself establish measurement accuracy or long-term outdoor stability. |
| Long-term stability and maintenance | Ask about drift, contamination sensitivity, recommended inspection intervals, cleaning restrictions, and field-replacement procedures. | Drift or endurance data, maintenance guidance, and documented procedures for recalibration or sensor replacement. | Compare expected maintenance effort and recalibration needs over the planned service life, not just initial purchase specifications. |
| Output and system compatibility | Confirm electrical output, supply requirements, connector type, cable limits, and compatibility with the weather station data logger. | Wiring diagram, interface protocol documentation, electrical specifications, and integration or communication test results. | Verify the exact signal and protocol required by the logger. Common industrial or meteorological interfaces include analog outputs, RS-485-based protocols, and SDI-12, but availability must be confirmed for each model. |
| Manufacturing and quality controls | Evaluate production consistency, incoming-material controls, final inspection, lot identification, and handling of nonconforming products. | Quality-management documentation, sample inspection records, production traceability information, and an explanation of corrective-action procedures. | Certification to a quality-management standard such as ISO 9001 can indicate a documented management system; it does not, by itself, prove that a particular sensor meets its performance claims. |
| Testing and reliability evidence | Check how the manufacturer validates performance under temperature, humidity, vibration, and other relevant environmental stresses. | Test plans and reports identifying sample sizes, test conditions, acceptance criteria, and whether tests were performed internally or by an independent laboratory. | Look for test methods relevant to the intended installation. IEC 60068 includes environmental testing methods, but the applicable tests and severities should match the use case. |
| Documentation and change control | Review the clarity and consistency of datasheets, installation instructions, revision history, and notification procedures for product changes. | Current controlled documents, model-specific specifications, and a written change-notification policy. | Ensure the quoted configuration, drawings, and technical specifications correspond to the exact model being evaluated. |
| Supply, warranty, and support | Clarify production lead time, minimum order quantities, warranty coverage, spare-part availability, and technical support arrangements. | Written quotation, warranty terms, stated lead-time assumptions, service contact process, and spare-parts policy. | Compare total ownership factors, including calibration, replacement, shipping, and support, rather than purchase price alone. |
| Application-specific acceptance criteria | Define required accuracy, response time, environmental limits, interface, and maintenance interval before comparing suppliers. | A written requirements checklist and a completed specification-compliance matrix for each candidate sensor. | There is no single accuracy or durability threshold suitable for every weather station. Set acceptance limits according to the monitoring purpose, site conditions, and data-quality requirements. |