| Regulatory reference | 21 CFR § 177.2600 covers rubber articles intended for repeated use in contact with food, subject to the regulation’s conditions. | Check that any compliance claim identifies the applicable regulation and applies to the finished article, not merely to a raw-material description. |
| Water extraction — first period | For the specified water-extraction test, extractives must not exceed 20 mg per square inch during the first 7 hours of refluxing with water. | Look for test documentation that states the test method, extraction medium, duration, and result. |
| Water extraction — second period | After the first extraction, extractives must not exceed 1 mg per square inch during a further 2 hours of refluxing with water. | Confirm that documentation reports the second extraction period as well as the first; the two limits apply to separate periods. |
| Fatty-food extraction benchmark | Under the regulation’s specified n-hexane extraction test, the limits are 175 mg per square inch for the first 7 hours and 4 mg per square inch for the following 2 hours. | Do not treat the water-extraction figures as the only relevant test when the intended food-contact conditions involve fatty foods. |
| Roll width and length | These are product dimensions, not FDA-set food-contact limits. There is no single FDA-required width or length for a silicone mat roll. | Compare the listed width and roll length with your work surface, storage space, and intended cutting needs. |
| Thickness and surface construction | 21 CFR § 177.2600 does not establish a universal preferred mat thickness or surface pattern. | Use the product’s published specifications; do not infer food-contact compliance from thickness, appearance, or texture alone. |
| Temperature range | The regulation’s extraction limits do not specify a universal oven-temperature rating for every silicone mat. | Check the stated temperature range and use instructions for the specific finished mat, including any limits on direct flame or broiler use. |
| Evidence and traceability | The extraction limits are test criteria; meeting them does not by itself establish every aspect of a product’s suitability for every food, use, or temperature. | Prefer product-specific documentation that identifies the material, intended repeated-use conditions, and relevant test results. |
| How to interpret the headline limits | The 20 mg/in² and 1 mg/in² figures are conditional water-extraction limits in 21 CFR § 177.2600. They are not a universal product rating, a guaranteed result for every silicone mat, or an FDA endorsement of a particular item. |