| Manual or semi-automatic probe station | Commonly 100–200 mm; some configurations accommodate smaller samples or larger wafers. | Often ambient; heated or cooled chuck options depend on configuration. Many systems support a range extending to approximately 200°C or higher when equipped for hot testing. | Operator loads and aligns the wafer or die; microscope-assisted positioning and probe movement are typical. | Engineering evaluation, failure analysis, low-volume testing, and device characterization. | Check microscope access, chuck flatness, probe compatibility, temperature uniformity, and how repeatable manual alignment needs to be. |
| Fully automatic wafer prober | Usually designed for 200 mm or 300 mm wafers; support depends on the selected platform and handlers. | Ambient testing is common; temperature-controlled configurations may cover sub-ambient and elevated temperatures, often up to about 150–200°C or more. | Automated wafer loading, alignment, die stepping, and test-site positioning support repeatable wafer-level measurement. | Production wafer sort, electrical screening, parametric testing, and high-volume device testing. | Compare wafer-size compatibility, throughput, alignment repeatability, interface support, and compatibility with the intended tester and probe card. |
| High-temperature wafer prober | Available for common wafer formats, including 150 mm, 200 mm, and 300 mm, depending on the system. | Elevated-temperature operation is configuration-specific; some systems are designed for chuck temperatures of approximately 200–300°C. | May use manual, semi-automatic, or automatic positioning; thermal stabilization is important before measurements. | High-temperature characterization of power, automotive, and other devices requiring hot testing. | Verify maximum chuck temperature, thermal uniformity, stabilization time, probe-card temperature limits, and safety provisions. |
| Low-temperature or cryogenic-capable prober | Often configured for wafer-level testing or smaller samples; supported diameters vary by platform. | Options may include sub-ambient testing, with some specialized systems reaching cryogenic temperatures. The achievable range depends on the cooling method and configuration. | Requires temperature-controlled chucking and attention to condensation, thermal contraction, and probe alignment. | Characterization of low-temperature electronics, sensors, and semiconductor devices. | Confirm the specified minimum temperature, cooldown time, vacuum or purge requirements, temperature stability, and compatibility of probes and cabling. |
| RF and high-frequency wafer prober | Commonly configured for 100–300 mm wafers or dedicated test substrates, depending on the application. | Usually ambient by default; temperature-controlled options may be available for selected platforms. | Designed to position RF probes and calibration substrates accurately; vibration control and cable management can be important. | On-wafer RF, microwave, millimeter-wave, and high-frequency device characterization. | Assess probe-station bandwidth, calibration approach, shielding, chuck design, vibration performance, and measurement-system compatibility. |
| Optical or optoelectronic wafer prober | Wafer and sample sizes vary with the optical access and device format required. | Ambient operation is common; temperature-controlLed Testing is available on selected configurations. | Combines electrical probing with optical access, alignment, or fiber-positioning equipment. | Testing of photonic devices, LEDs, laser components, and optical sensors. | Check optical access, alignment repeatability, working distance, light-control requirements, and integration with electrical instruments. |